Model: ICU Ventilator with Air Compressor FM-7250C (Constant Volume and Constant Pressure)
手术呼吸机了-in standby air compressor, can connet external air source, it is used for respiratory support and respiratory therapy in adult patients.
Our unwavering dedication to the highest quality materials and standards ensures theFully Automated Chemistry Analyzer,radiant heat warmer,pericarditis ecgwill not only be a pleasure to use but also be extremely durable. In recent years, our company's reputation has been rising, which is the result of our constant pursuit. We hope to sincerely build business relationships with customers from at home and abroad, jointly striving for a resplendent tomorrow.
Main technical parameters of ICU Ventilator Machine
■Display mode | High-definition 10.4” TFT color LCD screen display |
■Ventilation mode | IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH,IMV, VCV, PCV |
■Ventilation parameters | Tidal volume: 20~1500 ml Rate:1~99 bpm SIMV rate:1~20 bpm 我:E: 4:1 ~ 1:8 Inspiratory trigger pressure :-1.0~2.0Kpa PEEP:0~2.0Kpa Pressure range:1.0~6.0Kpa SIGH: 1.5 times the inspiratory time(70-150 adjustable) Inspiratory platform:0~50% |
■Parameters for ventilation monitoring | Tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform (autonomous inspiratory rate, lung compliance, airway resistance, flow -volume loop, pressure-volume loop) |
■Monitoring of oxygen concentration | 21%~100% |
■Security Alarm System | Oxygen Concentration alarm:upper limit setting range 21%~100% low limit setting range 10%~80% Airway pressure alarm: upper limit setting range 0.3~6.0 kPa low limit setting range 0.2~5.0 kPa Per-minute ventilation volume alarm: upper limit setting range 3.0~30L/min low limit setting range 1.0~10L/min Sustained high-pressure alarm: It will give alarm when stress have consistently been higher than 2.5 kPa Suffocation alarm: It will give sound and light alarm if there is no tidal volume input for 15 seconds. |
■Power | AC 220V±10% 50Hz±1Hz UPS, Storage battery |
■Mechanical Arms | |
■Air Compressor |
In order to make the Ambulance Portable Oxygen Breathing Machine S1100 Superstar Ventilator more efficient and convenient, we constantly develop and apply new technologies to improve it. At the same time, we hope to discuss the new development of product technology with colleagues in the industry, and look forward to providing customers with information consultation and technical support. We hope that our company will become the world card of China and realize the mission of revitalizing the national spirit and serving the country with industry!