Full Medical Co., Ltd
Add:9#, Wanzhen Xiaoyao Garden,Ma Anshan Road, Baohe Zone, Hefei City, Anhui Province, China.
Contact:Julie Chu (Sales Mananager)
Tel:+86-551-62625362
Mob:+86-18005568851
Email:sales@fullmedi.com
Email:info@fullmedi.com
Model: ICU Ventilator with Air Compressor FM-7250C (Constant Volume and Constant Pressure)
The surgery ventilator built-in standby air compressor, can connet external air source, it is used for respiratory support and respiratory therapy in adult patients.
Our aim is to provide customers with a full range of24小时ecg,incubator for preterm babies,Medical Bedand high-quality and thoughtful service. We actively explore post incentive methods to encourage creative work, so as to improve work efficiency. Our company's operating principles people-oriented, integrity management, innovation, mutual benefit and common development. We hope that our employees and managers should have a clear role, have the courage to take responsibility and think carefully.
Main technical parameters of ICU Ventilator Machine
■Display mode | High-definition 10.4” TFT color LCD screen display |
■Ventilation mode | IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH,IMV, VCV, PCV |
■Ventilation parameters | Tidal volume: 20~1500 ml Rate:1~99 bpm SIMV rate:1~20 bpm 我:E: 4:1 ~ 1:8 Inspiratory trigger pressure :-1.0~2.0Kpa PEEP:0~2.0Kpa Pressure range:1.0~6.0Kpa SIGH: 1.5 times the inspiratory time(70-150 adjustable) Inspiratory platform:0~50% |
■Parameters for ventilation monitoring | Tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform (autonomous inspiratory rate, lung compliance, airway resistance, flow -volume loop, pressure-volume loop) |
■Monitoring of oxygen concentration | 21%~100% |
■Security Alarm System | Oxygen Concentration alarm:upper limit setting range 21%~100% 下限设定范围10% ~ 80% Airway pressure alarm: upper limit setting range 0.3~6.0 kPa low limit setting range 0.2~5.0 kPa Per-minute ventilation volume alarm: upper limit setting range 3.0~30L/min low limit setting range 1.0~10L/min Sustained high-pressure alarm: It will give alarm when stress have consistently been higher than 2.5 kPa Suffocation alarm: It will give sound and light alarm if there is no tidal volume input for 15 seconds. |
■Power | AC 220V±10% 50Hz±1Hz UPS, Storage battery |
■Mechanical Arms | |
■Air Compressor |
With professional manufacturing capabilities and service spirit, we provide customers with stable performance En14683 Hospital Use Earloop 3 Ply Virus Breathable Face Mask Protective Respirator. The achievement of an enterprise comes from the support of the society. When an enterprise has success, it must take it from the society and strive to repay the society. We are committed to creating an inclusive culture and environment where we value, respect and support our employees to be themselves.
Sy-Hc021b Portable Digital 12 Leads Touch Screen ECG EKG Machine
Baby Heart Beat Sound Monitor Portable Ultrasound Device Doppler Manufac...
Mx-101c High Frequency Mobile System X-ray Equipment with Flat Panel Det...
Hospital Veterinary Medical Portable IV Syringe Infusion Pump Price
Medical Equipment Hospital First Aid Portable Biphasic External Aed Defi...