Full Medical Co., Ltd
Add:9 #, Wanzhen逍遥花园,马鞍山路,Baohe Zone, Hefei City, Anhui Province, China.
Contact:Julie Chu (Sales Mananager)
Tel:+86-551-62625362
Mob:+86-18005568851
Email:sales@fullmedi.com
Email:info@fullmedi.com
Model: ICU Ventilator with Air Compressor FM-7250C (Constant Volume and Constant Pressure)
The surgery ventilator built-in standby air compressor, can connet external air source, it is used for respiratory support and respiratory therapy in adult patients.
With the rapid development of the industry, our company continues to study and master the key technologies and developicu monitor,incubator baby,fetal doppler usewith independent intellectual property rights. Our products have won unanimous praise from people in the industry for their stable and reliable quality, high firing rate, reasonable price, and efficient service. We help customers increase value, achieving mutual benefit and win-win results. At the time of our marketing network is all over the world, we provide timely, perfect and comprehensive sales service for all our customers, so that enterprises and customers are closely connected to create a better future together. As long as you order our products, no matter where you are, we will dispatch technicians to serve you in time.
Main technical parameters of ICU Ventilator Machine
■Display mode | High-definition 10.4” TFT color LCD screen display |
■Ventilation mode | IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH,IMV, VCV, PCV |
■Ventilation parameters | Tidal volume: 20~1500 ml Rate:1~99 bpm SIMV rate:1~20 bpm 我:E: 4:1 ~ 1:8 Inspiratory trigger pressure :-1.0~2.0Kpa PEEP:0~2.0Kpa Pressure range:1.0~6.0Kpa SIGH: 1.5 times the inspiratory time(70-150 adjustable) Inspiratory platform:0~50% |
■Parameters for ventilation monitoring | Tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform (autonomous inspiratory rate, lung compliance, airway resistance, flow -volume loop, pressure-volume loop) |
■Monitoring of oxygen concentration | 21%~100% |
■Security Alarm System | Oxygen Concentration alarm:upper limit setting range 21%~100% low limit setting range 10%~80% Airway pressure alarm: upper limit setting range 0.3~6.0 kPa low limit setting range 0.2~5.0 kPa Per-minute ventilation volume alarm: upper limit setting range 3.0~30L/min low limit setting range 1.0~10L/min Sustained high-pressure alarm: It will give alarm when stress have consistently been higher than 2.5 kPa Suffocation alarm: It will give sound and light alarm if there is no tidal volume input for 15 seconds. |
■Power | AC 220V±10% 50Hz±1Hz UPS, Storage battery |
■Mechanical Arms | |
■Air Compressor |
According to the needs of different markets, we can provide our customers with high quality and cost-effective Hv-100d Transport Portable Emergency Ventilator Machine Breathing Apparatus and services. We strive to strengthen safe and compliant operations and create social and economic value. We hope that our employees will be grateful for the employment opportunities and talent platform provided by the enterprise.
12.1inch WiFi Central Monitor Multipara Patient Monitor (SNP9000N)
Sonosat-F02p Reasonable Price Medical Portable OLED Fingertip Pulse Oxim...