Home>Showroom
联系我们

Full Medical Co., Ltd

添加:9#, Wanzhen Xiaoyao Garden,Ma Anshan Road, Baohe Zone, Hefei City, Anhui Province, China.

Contact:Julie Chu (Sales Mananager)

电话:+86-551-62625362

暴民:+86-18005568851

电子邮件:sales@fulledi.com.
电子邮件:info@fullmedi.com

Medical Renal Failure Patient Used Hemodialysis Machine

Medical Renal Failure Patient Used Hemodialysis Machine

Model: FMT2008D Hemodialysis Machine

Through the implementation of automation, high-end and internationalization strategies, our company optimizes and adjusts the industrial structure, continuously improves product quality and efficiency, and strives to build the company into a benchmark in theair ventilator,ICU床,lung ventilator行业。如今,现代企业的竞争越来越多的人力资本竞争。如何获得,保留和激励人力资本是获得企业核心竞争力的关键。我们公司一直忠诚,诚实,尽力适应市场的不同需求,为客户提供完善的服务和产品。我们希望建立符合现代企业体系要求的人才培训,选择,评估和激励抑制机制。我们不仅重视产品技术和质量,而且更愿意为客户提供满意,保证和无忧的服务。

本设备的主要性能

1. Self-checking function;

2. Carbonate dialysis;

3. Double needle dialysis;

4. Liquid level detector;

泡沫探测器;

6. Blood leakage detector;

7.Temperature and electric conductivity monitoring;

8. Arterial pressure, venous pressure and transmembrane pressure monitoring;

9. Rolling blood pump;

10. Heparin pump;

11. Dehydration amount controlled by capacity;

12. Automatic disinfection cleaning program;

13. Stand-by power of blood pump in case of power failure;

14. Information display function of display screen.


Technical Data

1.General data

Dimensions : 1380 x 380 x 400 mm (H x W x D);

Weight approx.: 88 KG;

2.Water supply

Water inlet pressure: 1.5-6.0 bar

Water inlet temperature: 5℃~32℃

Max. drain height: 1m

3.Concentrate supply

Supply pressure: 0 to 2 m suction height

4.Electrical data

Power supply: AC220V±10%, 47-63HZ

Current consumption max.: max. 10 A

5.Extracorporeal circuit

动脉压力监测

显示范围:-380 mmhg至+400 mmhg

Accuracy: ±10 mmHg

Resolution: 1 mmHg

6.Venous pressure monitoring

Display range: -180 mmHg to +600 mmHg

Accuracy: ±10 mmHg

Resolution: 1 mmHg

7.Transmembrane pressure monitoring

Display range: -180 mmHg to +600 mmHg

Accuracy: ±20 mmHg

Resolution: 1 mmHg

8.Reartial血液泵

血流范围:8 mm血线系统中30至600ml / min

Accuracy: ±10%

9.泡沫泵

通过超声波传输,静脉夹中的额外光学监测。

10.肝素泵

Delivery range: 0ml/h to 10ml/h

Bolus function max.: 20 mL per bolus

Syringe size: 10, 20, 30, 50ml

11.Dialysis fluid circuit

Dialysis fluid flow range

Selectable: 100-800 mL/min

12.Dialysis fluid temperature

可选的:34.0℃到40.0℃

13.Dialysis fluid conductivity

范围:12至16 ms / cm(25℃)

Accuracy: ±0.1 mS/cm

14.Acid concentration dialysis fluid

Default mixing ratio: 1+34 (others possible)

Range: 125 to 150 mmol/L

15.碳酸氢盐浓度透析液体

Default mixing ratio: 1+27.6 (others possible)

Range: -8 to +8 mmol/L bicarbonate

16.Ultrafiltration

UF rate: 0ml/h~4000ml/h

Accuracy: ±1%

允许透析器UF因子:无限制

Parameter displayed: UF goal, UF time, UF rate, UF volume

17.Blood leak detector

Sensitivity: ≤0.35 mL blood/min (HCT=32)

KT/V

Calculation

18. Disinfection和清洁计划

Rinse

Temperature/flow: 30 to 60℃ / 300 to 800ml/min

Hot Rinse (recirculation)

Temperature/flow: 30 to 85℃ / 300 to 800ml/min

用化学品热消毒

Temperature/flow: 30 to 85℃/ 300 to 800ml/min

Various program combination selectable


Technical Data-Options

血压计(BPM)(可选功能)

Display range, Systole: 40-280 mmHg

舒张:40-280 mmhg

Accuracy: 1 mmHg

Central Delivery system for acid conc.

Supply pressure: 0 to 100 mbar;

1 m suction height with Central delivery system: 0-500 mbar

内毒素过滤器 - 透析流体过滤系统(可选功能)

Balancing accuracy: ±0.1% of dialysate flow

Bicarbonate dry

Concentrate: Bi-cart (optional function)

很长一段时间,公司建立了一支优秀的管理团队,与医疗肾功能衰竭患者使用血液透析机行业作为支柱,市场需求作为柱子,以及全国各地的营销网点。。我们主动了解客户的需求,预计市场变化,并提出了创新的解决方案。我们希望将员工在轻松的环境中愉快地工作,并使企业永远保持活力和活力。

热点标签:血液透析机,中国,供应商,制造商,厂家,批发,购买,便宜,报价,低价,pericarditis ecg,Fully Automated Chemistry Analyzer,便携式X射线机,ENT单位价格,invasive ventilator,blood oxygen meter