Model: Electronic Spirometer / Pulmonary Function Analyzer FM-MSA99
Each of ouranesthesia workstation,premature baby incubator,Dental Autoclaveis made of high-quality raw materials, which is the bearing of experience and creativity. We have formed a world-leading technology system and a service culture that makes customers satisfied with our heart. Welcome new and old customers to consult.
*便携pulmonary function measurement instrument can be used to measure vital capacity (VC), forced vital capacity (FVC), Maximum Ventilation Volume (MVV). Measurement algorithm refers to the ITS, ERS standards of the American Thoracic Society (ATS)
*Adopting pressure-flow sensor, sensitive, precise, easy to launder, clean and durable
*All parameters can be displayed on the oversized screen(320x240), built-in memory can store maximum 300 cases of patient measurement results
*The instrument can calibrate automatically, all English operation, more convenient to operate
*110mm thermal printer built-in, can print out a clear clinical report, predicted value, measured value
*Measurement of breathing time: VC time 50 seconds, FVC measuring time 25 seconds, MVV time 12 seconds, in favor of the coordination between patients and the device
*Compact and flexible
Items |
Technique specification |
Display Screen |
Diagonal line 5.7inches |
Monochrome LCD |
|
Resolution 320*240 |
|
Control |
Standard: UTILITY KEY,SVC KEY,FVC KEY,MVV KEY,PRINT KEY,10WORDS KEY, START KEY,STOP KEY |
Light alarm |
|
Measurement means |
Flow velocity detection: pressure gradient pneumatic flow sensor |
Capacity detection: flow velocity integral |
|
measuring range |
Capacity range: 0L ~ 9L |
Flow velocity range: 0 ~ 14L / s |
|
measurement accuracy |
Capacity: |
0L ~ 1.6L (± 50ml) |
|
6L ~ 9L (± 3%) |
|
Flow rate: 5% or 0.2L / s |
|
Respiratory rate: |
|
4 / 20 ~ / min (± 1 / min) |
|
20 / 60 / min (error: ± 5%) |
|
measuring time limit and degree |
Vital capacity: every 50s, measuring 3 |
FVC: per second, 25s, measuring 3 |
|
The maximum ventilation volume: every 12 seconds, measuring 3 |
|
Paper Recorder |
Method: dot matrix |
Level Resolution Ration: 8 d/mmspeed 25mm/s |
|
Uprightness Resolution Ration: 8 d/mm |
|
Wave Channels: 1 |
|
Paper Width: 110mm1.97inches |
|
Paper Length: 15m100inches |
|
Formfeed Speed: 12.5,25 and 50mm/s±2 |
|
Power supply |
AC: 100V~240V |
DC: rechargeable Nickel-metal hydride (NI-MH), 14.4-volt, 1.8 amp hour |
|
Fuse |
100V~240V ACF2A250V,5×20mm |
Safety classification |
IEC60601-1 class I, type CF |
We goal to understand excellent disfigurement from the manufacturing and supply the top support to domestic and abroad clients wholeheartedly for Medical Use Three Balls Spirometer for Deep Breathing Trainer with Ce ISO. Our faith is to be honest first, so we just supply high quality products to our customers. After several years of struggle, we finally found the experience, and have established matured business operations, marketing and customer relations.