Model: FM9020 12.1"TFT Display Multi-parameter monitor.
Standard configuration is ECG,RESP,NIBP,SPO2,PR,TEMP. Optional function is IBP,EtCO2,Cardiac output,printer.
We hope that the development of theoxygen meter finger,Medical Baby Radiant Warmer,fetal doppler useindustry in China will be different because of our existence. Each of our marketing staff will keep in touch with customers at all times, track the market reflection and use of the product, so as to provide corresponding technical support when necessary. Our confidence comes from our profession, our diligence, our sincerity, and your wisdom. We will move forward together with more vigorous vigor, high morale, pragmatic style and courage to explore. We cordially welcome shoppers from in the home and overseas to hitch us and cooperate with us to enjoy a better future.
Main Instruction of FM9020 Multi-parameter monitor
12.1''high resolution color TFT display
96 hours trend graphic data, 12-lead ECG analysis
Arrhythmia and S-T segment analysis
Anti-defibrillation, Anti-high frequency electrotome
Multi-language,easy operate,durable and stable
Calculation function of drug concentration , drug titration and hemodynamic status
Wired or wireless network
Three-level Audible and visible alarm, events recallable , Nurse Call Function
AC/DC power supply, built-in high capacity battery
Standard configuration
ECG,RESP,NIBP,SPO2,PR,TEMP
Optional function
IBP,EtCO2,Cardiac output,printer
Specification
Dimension(H*W*D): 272*327*145(mm)
Weight: 6.5kg (with battery)
ECG
Measuring: adult 0~300bpm; neonate and pediatric: 0~350bpm
Band width: 0.05Hz~100Hz
Accuracy: ±1%
Lead type: 5-lead and 3-lead selectable
Lead selection: standard I II, III; augmented limb lead aVR, aVL, Chest lead V1~V6
Resolution: 1bmp
Trend monitoring time: no less than 96 hours
st段分析:-2.0 mv ~ 2.0 mv;汽车
Arrhythmia analysis: 13 kinds of arrhythmia analysis
Scanning speed: 12.5, 25, 50mm/ second
Gain selection: *1/2, *1/, *2; auto
Protection: withstand 4000 VAC/50Hz voltage, voltage in isolation against, defibrillation and electrosurgical interference
ECG cable: adults, pediatric and neonate
Alarm range: 15~350bpm
ARR Alarm: audible and visible alarm, events recallable
SPO2
Measuring range: 0~100%
Resolution: 1%
Accuracy: ±1%(70%~100%), ±2%(0%~69%)
PR measuring range: 0~255bpm
PR accuracy: ±1 bpm
Sensor type: adult sensor (standard), pediatric sensor (optional), neonate sensor (optional)
Alarm range: 0~100%
RESP
Display: waveform display and numeric display
Operation mode: auto/ manual
Method: trans-thoracic impedance
RR measuring range: 0~150bpm
Accuracy: ±1 bpm
Apnea alarm threshold: 10s, 15s, 20s(default), 25s, 30s, 40s
Band width: 0.2~5Hz (-3dB)
Sweep speed: 6.25mm/s, 12.5mm/s, 50mm/s
Alarm range: adult:6-120rpm; pediatric and neonate: 6-150rpm
NIBP
Method: automatic oscillometric
Operation model: manual, automatic, continuous
Auto measurement time interval: adjustable 1/2/3/4/5/10/15/30/60/90/120/240/480 Min
Measuring unit: mmHg/ kPa selectable
Measuring range: adult 10-270mmHg; pediatric 10-200mmHg; neonate 10-135mmHg
Cuff pressure range: 0-320mmHg
Cuff type: adult cuff, pediatric, neonate
Over-pressure protection: yes
Alarm: upper alarm, lower alarm, auto-memory
TEMP
Measuring range: 0-50℃
Probe type: body temperature probe(standard), esophageal temperature probe(optional) rectal temperature probe(optional)
Resolution: 0.1℃
Accuracy: ±1℃
Channel: dual-channel, provide T1, T2
Alarm range: 0-50℃
IBP (Optional)
Measurement range: -10~300mmHg
Channel: 2 channels
Sensitivity: 5μV/V/mmHg
Impedance range: 300~3000Ω
Accuracy: ±1mmHg or ±2% (exclusive of transducer)
Alarm range: -10~300mmHg
EtCO2 (Optional)
Measurement range: -10~300mmHg
Accuracy: 1rpm
Sample flowerate: 50ml/min
Sample rate accuracy:±15% or 15ml/min
Respiration rage: 0~120rpm
Respiration accuracy: ±2rpm(0~70rpm); ±5rpm(>70rpm)
Respiration time: <60ms
Delay time: <2s
品牌可以让消费者有一种信任的感觉our Multipara Monitor Sleep Test for Sleep Apnea, and corporate culture can help enhance consumers' sense of identity. We firmly believe that "your demand is our demand, your satisfaction is our responsibility". We will continue to improve the innovation ability, enhance the scientific and technological content of the enterprise, and provide technical support for the transformation and development of the company.
Cheap Price Standard Jinling-01b Anesthesia Machine Hospital
Huc-300 Medical Hospital 2D 3D 4D 96 Elements Laptop Color Doppler Ultra...
HP-1e High Frequency Medical Surgical Leep Surgery System Electrosurgica...
My-B022f-N Windows Operation Fully Automatic Microplate Elisa Reader Mac...
Hot Selling Inhalation High Quality Inhalation Anaesthetic Machine Cwm-302