Non-Invasive Bipap Machine Ventilator

Non-Invasive Bipap Machine Ventilator

Model: ICU Ventilator with Air Compressor FM-7250C (Constant Volume and Constant Pressure)
The surgery ventilator built-in standby air compressor, can connet external air source, it is used for respiratory support and respiratory therapy in adult patients.

We are confident that it is possible to gain market share since we have such a excellentecg electrodes,anesthesia machine price,ultrasonic soundcombined with a good understanding of customers' needs. Driven by technological innovation and capital operation, we hope to make our business scale at the forefront of the industry through unremitting efforts and continuous changes. We are committed to scientific management system, diversified business philosophy, standardized after-sales service, networked distribution channels, and common logistics and distribution. We respect credit, abide by contracts, guarantee product quality, and have won the trust of our customers with a variety of operating characteristics and competitive prices.

Main technical parameters of ICU Ventilator Machine

■Display mode High-definition 10.4” TFT color LCD screen display
■Ventilation mode IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH,IMV, VCV, PCV
■Ventilation parameters

Tidal volume: 20~1500 ml

Rate:1~99 bpm

SIMV rate:1~20 bpm

我:E: 4:1 ~ 1:8

Inspiratory trigger pressure :-1.0~2.0Kpa

PEEP:0~2.0Kpa

Pressure range:1.0~6.0Kpa

SIGH: 1.5 times the inspiratory time(70-150 adjustable)

Inspiratory platform:0~50%

■Parameters for ventilation monitoring Tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform (autonomous inspiratory rate, lung compliance, airway resistance, flow -volume loop, pressure-volume loop)
■Monitoring of oxygen concentration 21%~100%
■Security Alarm System

Oxygen Concentration alarm:upper limit setting range 21%~100%

low limit setting range 10%~80%

Airway pressure alarm: upper limit setting range 0.3~6.0 kPa low limit setting range 0.2~5.0 kPa

Per-minute ventilation volume alarm: upper limit setting range 3.0~30L/min low limit setting range 1.0~10L/min

Sustained high-pressure alarm: It will give alarm when stress have consistently been higher than 2.5 kPa

Suffocation alarm: It will give sound and light alarm if there is no tidal volume input for 15 seconds.

■Power AC 220V±10% 50Hz±1Hz UPS, Storage battery
■Mechanical Arms
■Air Compressor


We warmly welcome our regular and new consumers to join us for Non-Invasive Bipap Machine Ventilator. In terms of corporate culture, we adhere to the people-oriented, user-oriented development approach, and strengthen corporate social responsibility awareness. The company has excellent professionals, has absorbed international advanced management experience, implemented scientific management, advanced technology, equipped with scientific testing methods to ensure product quality, maintain corporate reputation, and provide users with excellent products and all customer-concentric service.

Hot Tags: ICU ventilator, China, suppliers, manufacturers, factory, wholesale, buy, cheap, quotation, low price,oximeter levels,digital x ray machine cost,hospital respirator,anaesthesia workstation,Elisa Plate Reader,baby incubator jaundice