Full Medical Co., Ltd
Add:9#, Wanzhen Xiaoyao Garden,Ma Anshan Road, Baohe Zone, Hefei City, Anhui Province, China.
Contact:Julie Chu (Sales Mananager)
Tel:+86-551-62625362
Mob:+86-18005568851
Email:sales@fullmedi.com
Email:info@fullmedi.com
Model: Electronic Spirometer / Pulmonary Function Analyzer FM-MSA99
We adopt high-quality raw materials to make our血红素atology Analyser,Dental Chair,fetal heart detectormore durable and environmentally friendly. We always attach importance to the cultivation of talents. After years of hard work, we have formed a pragmatic, truth-seeking and perfect corporate culture. Long-term partnership and fruitful cooperation is our goal, we hope that with our strong spirit of innovation and initiative, can accompany our customers and partners struggle together. We hope that our employees will continue to learn and progress in their work, strive to improve their self-quality and cultivation, and do their job better.
*The portable pulmonary function measurement instrument can be used to measure vital capacity (VC), forced vital capacity (FVC), Maximum Ventilation Volume (MVV). Measurement algorithm refers to the ITS, ERS standards of the American Thoracic Society (ATS)
*Adopting pressure-flow sensor, sensitive, precise, easy to launder, clean and durable
*All parameters can be displayed on the oversized screen(320x240), built-in memory can store maximum 300 cases of patient measurement results
*The instrument can calibrate automatically, all English operation, more convenient to operate
*110mm thermal printer built-in, can print out a clear clinical report, predicted value, measured value
*Measurement of breathing time: VC time 50 seconds, FVC measuring time 25 seconds, MVV time 12 seconds, in favor of the coordination between patients and the device
*Compact and flexible
Items |
Technique specification |
Display Screen |
Diagonal line 5.7inches |
Monochrome LCD |
|
Resolution 320*240 |
|
Control |
Standard: UTILITY KEY,SVC KEY,FVC KEY,MVV KEY,PRINT KEY,10WORDS KEY, START KEY,STOP KEY |
Light alarm |
|
Measurement means |
Flow velocity detection: pressure gradient pneumatic flow sensor |
Capacity detection: flow velocity integral |
|
measuring range |
Capacity range: 0L ~ 9L |
Flow velocity range: 0 ~ 14L / s |
|
measurement accuracy |
Capacity: |
0L ~ 1.6L (± 50ml) |
|
6L ~ 9L (± 3%) |
|
Flow rate: 5% or 0.2L / s |
|
Respiratory rate: |
|
4 / 20 ~ / min (± 1 / min) |
|
20 / 60 / min (error: ± 5%) |
|
measuring time limit and degree |
Vital capacity: every 50s, measuring 3 |
FVC: per second, 25s, measuring 3 |
|
The maximum ventilation volume: every 12 seconds, measuring 3 |
|
Paper Recorder |
Method: dot matrix |
Level Resolution Ration: 8 d/mmspeed 25mm/s |
|
Uprightness Resolution Ration: 8 d/mm |
|
Wave Channels: 1 |
|
Paper Width: 110mm1.97inches |
|
Paper Length: 15m100inches |
|
Formfeed Speed: 12.5,25 and 50mm/s±2 |
|
Power supply |
AC: 100V~240V |
DC: rechargeable Nickel-metal hydride (NI-MH), 14.4-volt, 1.8 amp hour |
|
Fuse |
100 v ~ 240 v ACF2A250V, 5×20毫米 |
Safety classification |
IEC60601-1 class I, type CF |
We will strictly abide by our commitments, be proactive, further increase investment in research and development of Spirometer System, Portable Pulmonary Function with Built in Memory up to 300 Cases, develop better products to share with users, and sincerely provide quality services to users. Our company adheres to continuous innovation, keeps pace with the world's advanced technology and meets the needs of different users through continuous improvement. We are strict with every part of our work.
Biobase LCD Display Class II A2 Biological Safety Cabinet NSF Certificated
Korea Ret RF Diathermy Therapy Body RF Monopolar Slimming Machine